Prioritizing our health and well-being is critical in the fast-paced environment we live in today. Monitoring vital signs is essential for the early identification of health problems and the efficient management of diverse illnesses. The Nellcor Pulse Oximeter is distinguished as a dependable and precise tool that enables users to conveniently check their oxygen levels. We will examine the capabilities of this Oximeter in this blog post, emphasizing how it can assist people in maintaining good health.
Principles of the Nellcor Pulse Oximeter
In order to calculate the oxygen saturation levels, the Nellcor Pulse Oximeter uses spectrophotometry, which measures light absorption. The apparatus produces precise measurements by generating two wavelengths of light and examining the difference in absorbance of oxygenated and deoxygenated hemoglobin. In difficult circumstances, signal processing methods ensure accurate measurements by removing interference. In order to monitor one’s health, the oximeter shows real-time Saturation of Peripheral Oxygen (SpO2) and pulse rate data. Alarms that can be customized as well as trend monitoring enable tracking of changes over time and allow for individual settings. Convenient oxygen saturation monitoring is made possible by the device’s robustness and portability, which make it suited for a variety of healthcare contexts.
Models of Nellcor Pulse Oximeter
Medtronic Nellcor PM10N Pulse Oximeter
- Weight: 0.60 lbs.
- Dimensions: W- 2.76 in, H- 6.14 in, D- 1.26 in
- Resolution:320 x 480 pixels
- SpO2 range:1-100%
- Pulse rate rang3: 25-250 beats per minute
- Display sweep speed: 6.25 mm/sec
- Screen size: 3.5 in diagonally
- Screen type: TFT LCD
- Batteries: Lithium AA
Nellcor Original DS100A SpO2 Sensor
- Weight: 0.22 lbs.
- Cable length: 42 in
- Display: Digital
- Patient size: > 88 lbs
- Connector distal: Male 9-Pin 3D-sub purple
Nellcor DuraY Sensor Neonatal Multisite
- Weight: 0.23 lbs.
- Cable length: 42 in
- Display: Digital
- Patient size: Infants
- Connector distal: Male 9-Pin 3D-sub purple
N-395 Pulse Oximeter
- SpO2: 1 – 100%
- Pulse Rate: 20 – 250 beats per minute (bpm)
- Sensor wavelength range: 250 nm to 1,000 nm
- Battery Type: Lead-Acid
- Weight: 5.7 lbs.
- Dimensions: 3.3 in. x 10.4 in. x 6 .8 in
- Temperature: – (-4°F to +158°F)
- Pressure: 106 kPa to 50 kPa
Alaris Medley SpO2 Module 8210 Nellcor
- Perfusion: 0.03-20%
- Pulse rate: 20-250 beats per minute
- SpO2: 1-100%
- Wavelength: 500-1000 nm
- Operating ambient temperature:41-105oF
- Operating ambient pressure:700-6080 hPa
- Dimension: H- 8.9in, W- 3.3in, D-5in
- Weight: 2 lbs
- Alarm: Audible and visual alarms.
Nellcor Compatible saturation module
- Dimension: W- 1.5 in, D-7.44 in, H-4.4 in
- Weight: 0.7 lbs
- Measurement method: red and infrared light absorption
- Pulse rate Range: 20 to 300 bpm
- Accuracy: ± 3 bpm
- Display average time: 5 to 7 seconds
Nellcor Bedside SpO2 Patient Monitoring System
- Weight: 3.5 lbs.
- Dimensions: 10.04 x 3.23 x 6.50 in
- Display Screen size: 4.3 in diagonally
- Screen type: TFT LCD, white LED backlight
- Resolution: 480 × 272 pixel
- Alarm volume level: 45 to 80 dB
- Battery power requirement: AC 100-240VAC, 50/60Hz,
- Voltage: 10.8 V/ 2200 mAh
- Operating ambient temperature: 41-105oF
Medtronic Nellcor PM10N Handheld Pulse Oximeter
- Weight: 0.604 lbs including four batteries
- Dimensions: 2.76 in W x 6.14 in H x 1.26 in D
- Display Screen size: 3.5 in
- Resolution: 320 x 480 pixels
- Alarm volume level: 49 to 89 dB
- SpO2 saturation range: 1% to 100%
- Pulse rate range: 20 to 250 beats per minute (bpm)
- Perfusion range: 0.03% to 20%
- Display sweep speed: 6.25 mm/sec
- Memory: 80
- Operating ambient temperature: 41-105oF
Oximax N-560 Pulse Oximeter
- SpO2: 1% to 100%
- Pulse Rate: 0 and 20 beats per minute (bpm) to 250 bpm
- Perfusion Range: 0.03% to 20%
- Battery Type: Nickel metal hydride
- Voltage: 9.6 Volts DC
- Ambient operating Temperature: -4 ºF to 140 ºF
- Ambient operating pressure: 50 kPa to 106 kPa
- Weight: 3.07 lbs.
- Dimensions: H- 2.95in, W- 9.06in, D-5.04in
- Mode of operation: Continuous
OXIMAX N-600X Pulse Oximeter
- Weight: 5.8 lbs.
- Dimensions: 3.3 in. x 10.4 in. x 6.8 in
- Battery Type: Lead acid
- Voltage: 6 Volts DC
- %SpO2: Saturation Range 1% to 100%
- Pulse Rate Range: 20 to 250 beats per minute (bpm)
- Perfusion Range: 0.03% to 20%
- Temperature: -4 ºF to 140 ºF
- Atmospheric Pressure: 50 kPa to 106 kPa
Nellcor™ N-85 Hand-Held Capnograph/Pulse Oximeter
- Display Range: 0% to 100%
- Pulse Rate: 20 to 250 beats/minute
- Battery Type: Rechargeable NiMH
- Operating temperature: 32°F to 113°F
- Weight: 1.87 lbs.
- Size: H-8.11 in x W-3.46 in x D-2.06 in
Maintenance of the Pulse Oximeter
- Cleaning: Using a gentle, lint-free cloth or a non-abrasive cleaning wipe, clean the pulse oximeter’s exterior on a regular basis.
- Cleaning and sanitizing the sensor: If the Nellcor pulse oximeter has a reusable sensor, clean and disinfect it according to the manufacturer’s recommendations to prevent cross-contamination.
- Testing and Calibration: In order to ensure the accuracy of Nellcor pulse oximeters, they may need to be tested or calibrated on a regular basis.
- Battery maintenance: Check the battery life of your pulse oximeter on a regular basis if it runs on batteries. Have extra batteries on hand in case the power goes out in an emergency.
- Storage: Keep the Nellcor pulse oximeter in a dry, clean, and secure place while not in use. Shield it from high humidity, severe temperatures, and even physical harm.
Conclusion
An essential medical tool for keeping track of patients’ oxygen levels is the Nellcor pulse oximeter. Its precision and dependability can be guaranteed with routine maintenance that includes cleaning, calibration, and appropriate storage. By following the instructions provided by the manufacturer and obtaining expert assistance, when necessary, this gadget can make a substantial improvement in patient care and safety. Healthcare practitioners may rely on the pulse oximeter’s performance to support prompt and precise medical treatments by remaining up to date with software releases and adhering to recommended alarm calibration. Another pulse oximeter you can read about forehead pulse oximeter and the toe pulse oximeter.