Best Electrolyte Analyzers to use in clinical and research laboratories
An electrolyte analyzer is a device used to detect and measure the concentrations of electrolytes like sodium, potassium, and chloride in biological samples like urine, whole blood, plasma, or serum. Knowing the best electrolyte analyzer gives you a chance of diagnosing the right disease for a patient which will also aid in dispensing drugs and calling for surgeries. Without much I do, let us take a look at the best electrolyte analyzers to use in clinical and research laboratories. Find out about gazelle HB variant.
List of the Best Electrolyte Analyzers
Cornley AFT-800 Electrolyte Analyzer
Mode of operation | Fully automated |
Principle of operation | Ion Selective Electrode |
Control | Touchpad |
Sample | Plasma, serum, whole blood, urine |
Parameters | Sodium (Na+), Potassium (K+). Chloride (Cl–). Lithium (Li+). Calcium (Ca=2), Carbon dioxide in serum only, and pH |
Calibration | Automatic and manual |
Sample volume | 80 ul |
Test duration | 25 seconds |
Weight | 26.4 lbs. |
Dimensions | 13.3in x 11.1in x 17.9in |
Voltage required | 100-240 volts |
Room temperature | 41oF- 104oF |
Atmospheric pressure | 86,000-106,000 Pascal |
Storage | 10,00 results and 1000 quality control results with L-J charts |
Alarms | Clot alarm (automatic and manual), bubble alarm |
Screen resolution | 7in screen with 800 x 400 pixels |
Printer | In-built thermal printer with 240 x 280 pixels |
Others | Calculates reagent consumption, electrode maintenance alert |
Price | $1,020.00 |
Nulyte Smart Electrolyte Analyzer
Mode of operation | Fully automated |
Electrolytes measured | Sodium (Na+), Potassium (K+). Chloride (Cl–). Lithium (Li+). Calcium (Ca=2) |
Sample | Whole blood, urine, plasma, serum, dialysate, cerebrospinal fluid |
Principle of operation | Direct measurement with Ion Selective Electrodes |
Sample volume | 100 ul |
Tests duration | 65 seconds |
Throughput | 60 tests in an hour |
Storage | 1000 results |
Control | Keypad |
Printer | In-built column thermal printer |
Room temperature | 41oF-104oF |
Voltage required | 220 V AC |
Dimension | W- 11.9 in x H- 13.8 in x D- 12.0 in |
Weight | 18.9 lbs. |
Price | $1.850.00 |
Easylyte Electrolyte Analyzer
Mode of operation | Automatic |
Principle of operation | Ion Selective Electrode |
Control | Yes and No keys |
Sample | Urine, whole blood, serum, plasma |
Sample volume | 100 ul of whole blood, serum, plasma. A 1:10 400ul dilution of urine |
Parameters | Sodium (Na+), Potassium (K+). Chloride (Cl–). Lithium (Li+). Calcium (Ca=2), and pH |
Test duration | 60 seconds |
Storage | 128 test results, 20 normal, low, normal and high-quality control tests |
Measurement range for blood, serum, plasma | Na+– 20-200 mmol/l K+– 0.2-40 mmol/l Cl–– 25-200 mmol/l Li+ – 0.2-5.0 mmol/l Ca=2– 0.1-6.0 mmol/l |
Measurement range for urine | Na+ – 25-1000 mmol/l K+ – 1.0-500 mol/l Cl—25-500 mol/l |
Room temperature | 60oF- 90oF |
Voltage required | 100-240 Volts |
Dimensions | 16.54 in x 9.45in x 7.87 in |
Weight | 12.79 lbs. |
Price | $2100.00 |
Roche 9180 Electrolyte Analyzer
Mode of operation | Fully automated |
Principle of operation | Ion Selective Electrode |
Sample | Whole blood, urine, serum, plasma, dialysate |
Sample volume | 95 ul |
Parameters | Sodium, Potassium, Chloride |
Test duration | 50 seconds |
Control | Yes and No keypad |
Calibration | Fully automated |
Test duration | 50 seconds |
Throughput | 60 samples per hour |
Printer | In-built thermal printer |
Weight | 13.2 lbs. |
Dimensions | 13.2in x 12.4in x 12.0 in |
Voltage required | 110-240 volts |
Values | Abnormal results are flagged |
Display | Dot matrix, 16 characters wide, 2 lines |
Mode | Standby is automatically or manually controlled |
Price | $3,500.00 |
Caretium XI-921 Electrolyte Analyzer
Mode of operation | Fully automated |
Sample | Whole blood, serum, plasma, urine |
Parameters | Sodium, potassium, chloride, calcium, lithium ad pH |
Principle of operation | Ion Selective Electrode |
Sample volume | 95 ul |
Control | Touchpad |
Tests duration | 28 seconds for the 1st time |
Throughput | 512 tests per hour |
Storage | 10,000 test results 10,000 quality control results |
Display | Digital |
Measuring range | K+– 0.50-15.00 mmol/l Na+– 30.0-200.0 mmol/l Cl– 30.0-200.0 mmol/l Ca+2 – 0.10-5.00 mmol/l Li+– 0.20-3.00 mmol/l pH- 4.00-9.00 unit |
Weight | 22.1 lbs. |
Price | $1,550.00 |
Sensacore ST-200 CL Electrolyte Analyzer
Mode of operation | Fully automated |
Sample | Whole blood, serum, plasma, cerebrospinal fluid, diluted urine |
Sample volume | 110ul |
Parameters | Sodium, Potassium, Ionized calcium, chloride, lithium and pH |
Test duration | 55 seconds |
Throughput | 60 tests per hour |
Principle of operation | Direct measurement with Ion Selective Electrode |
Control | Alphanumeric keypad |
Storage | 10,000 |
Room temperature | 410F-1040F |
Voltage required | 220 V AC |
Weight | 4.4 lbs. |
Language | English |
Price | $1,830.00 |
Meril Quantilyte Electrolyte Analyzer
Mode of operation | Fully automated |
Sample type | Whole blood, serum, plasma, cerebrospinal fluid, diluted urine |
Sample volume | Minimum of 60ul Maximum of 150 ul |
Parameters | Sodium, potassium, chloride, calcium and pH |
Principle of operation | Ion selective electrode |
Test duration | 25 seconds |
Throughput | 60 tests per hour |
Storage | 10,000 test results |
Control | Yes and No keypad |
Printer | In-built thermal printer |
Room temperature | 50oF-86oF |
Voltage required | 220V |
Weight | 13.3 lbs. |
Dimensions | W- 14.96 in x D- 10.63 in x H- 15.75 in |
Atmospheric pressure | 86,000-106,000 Pascal |
Price | $1,835.00 |
Besic CBS 40 Electrolyte Analyzer
Mode of operation | Fully automatic |
Principle of operation | Multi-biosensor |
Sample | Plasma, serum, aqueous solution, diluted urine |
Sample volume | Minimum 0f 120 ul Maximum of 150 ul |
Parameters | Sodium. Potassium, calcium, chloride, and pH |
Test duration | 30 seconds |
Throughput | 80 tests per hour |
Printer | In-built thermal printer |
Control | Touchpad |
Storage | 1000 test results |
Room temperature | 50oF-86oF |
Voltage required | 110-220 VAC |
Weight | 22.04 lbs. |
Dimensions | W- 17.32 in x D- 10.24 in x H- 18.50 in |
Price | $1,590.00 |
Arkray SPOTCHEM EL SE-1520 Electrolyte Analyzer
Mode of operation | Semi-automatic |
Principle of operation | Ion Selective Electrode |
Sample | Whole blood, serum, plasma, urine |
Sample volume | 25 ul |
Parameters | Sodium, potassium, chloride |
Test results | 60 seconds |
Throughput | 50 tests per hour |
Control | Alphanumeric keypad |
Principle | Potentiometry with Ion Selective Electrode |
Sample supply | Manual pipetting |
Printer | In-built thermal printer |
Storage | 50 test results |
Room temperature | 50oF-86oF |
Voltage required | 100-240 Volts |
Dimension | W- 5.31 in x D- 8.86 in x 5.43 in |
Weight | 3.31 lbs. |
Price | $1,950.00 |
Genrui GE300 Electrolyte Analyzer
Mode of operation | Fully automatic |
Sample | Urine, serum, plasma |
Sample volume | Minimum 100 ul Maximum 200 ul |
Parameters | Sodium, potassium, chloride, lithium |
Principle of operation | Ion selective electrode |
Control | Touchscreen |
Storage | 50,000 tests result |
Test duration | 55 seconds |
Throughput | 60 tests per hour |
Room temperature | 59oF-86oF |
Printer | In-built thermal printer |
Voltage required | 220 Volts AC |
Dimensions | W- 16.9 in x D- 10.8 in x H- 16.1 in |
Weight | 3.1 lbs. |
Price | $1,530.00 |
Diamond Prolyte Electrolyte Analyzer
Mode of operation | Fully automated |
Sample | Whole blood, serum, plasma, urine |
Sample volume | 140 ul |
Parameters | Sodium, potassium. Chloride, lithium |
Principle of operation | Ion selective Electrode |
Control | Touchpad or USB keyboard |
Test duration | 45 seconds |
Throughput | 240 tests per hour |
Storage | 100,000 test results |
Room temperature | 41oF-104oF |
Printer | In-built column thermal printer |
Voltage required | 220 Volts AC |
Dimension | W-15.0 in x D-12.0 in x H-7.0 in |
Weight | 13.3 lbs. |
Price | $1,850.00 |
Besic CBS 300 Electrolyte Analyzer
Mode of operation | Fully automated |
Sample | Plasma, serum, aqueous solution, diluted urine |
Sample volume | Minimum- 120 ul Maximum- 150 ul |
Parameters | Sodium, Potassium, Chloride |
Principle of operation | Multi-biosensor |
Control | Numeric keypad |
Storage | 1000 test results |
Throughput | 80 tests per hour |
Tests duration | 30 seconds |
Printer | In-built thermal printer |
Room temperature | 50oF-86oF |
Voltage required | 110-220 V AV |
Dimension | W- 17.3 in x D- 10.2 in x H- 18.5 in |
Weight | 22.0 lbs. |
Price | $1,350.00 |
Horiba Yumizen E100 Electrolyte Analyzer
Mode of operation | Fully automated |
Sample | Whole blood, serum, urine |
Sample volume | 95 ul- Whole blood, serum and plasma 180 ul – Urine |
Principle of operation | Ion Selective electrode |
Measurement range for blood, serum, plasma | K+– 1.6-15 mmol/l Na+-40-200 mmol/l Cl– 50-200 mmol/l Ca+2 – 0.3-5.0 mmol/l Li+– 0.20-5.5 mmol/ |
Measurement range for urine | K+– 5-120 mmol/l Na+– 3-300 mmol/l Cl– 15-300 mmol/l |
Parameters | Sodium, potassium, calcium and lithium |
Control | Touchpad or USB keyboard |
Storage | 10,000 test results 10,000 Quality control results |
Test duration | 28 seconds |
Throughput | 512 tests per hour |
Veterinary options | Swine, ovine, murine |
Room temperature | 600F -90oF |
Voltage required | 100- 240 V AC |
Dimension | W- 13.2 in x H- 12.4 in x D- 12 in |
Weight | 13.2 lbs. |
Price | $1,770.00 |
Final thoughts on the best electrolyte analyzers
Knowing the list of best electrolyte analyzers will give you a wide range of machines to choose from that can suit your preference. Reading about the principle of an Easylyte electrolyte analyzer will help you understand how Ion Selective Electrode technology works among the best electrolyte analyzers I have listed above. Another machine you must read about is the maglumi 800 Hormone analyzer.